logo
বাড়ি পণ্যমেডিকেল এয়ার ফ্লো সেন্সর

YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators

YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators

YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators
YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators

বড় ইমেজ :  YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators

পণ্যের বিবরণ:
উৎপত্তি স্থল: মার্কিন যুক্তরাষ্ট্র
পরিচিতিমুলক নাম: YJJ
মডেল নম্বার: পিএন 281637, পিএন 282049, পিএন 282051
প্রদান:
ন্যূনতম চাহিদার পরিমাণ: 1
মূল্য: আলোচনাযোগ্য
প্যাকেজিং বিবরণ: ব্যাগড
ডেলিভারি সময়: 5-8 দিন
পরিশোধের শর্ত: এল/সি, ডি/এ, ডি/পি, টি/টি, ওয়েস্টার্ন ইউনিয়ন, মানিগ্রাম
যোগানের ক্ষমতা: 1500

YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators

বিবরণ
প্রবাহ: 0 থেকে 30 এল/মিনিট মৃত স্থান: 1.3 এমএল (কার্যকরী)
প্রতিরোধ: <0.17 সেমিএইচ 2 ও/(এল/মিনিট) ওভার ওজন: প্রায় 9 জি
উপাদান: আইএসও 10993-1: 2009 এর সাথে সম্মতি জানায় নির্ভুলতা: ক্যালিব্রেটেড ফ্লো সেন্সর জন্য
বিশেষভাবে তুলে ধরা:

Haimont ventilator flow sensor

,

medical air flow sensor

,

proximal flow sensor with warranty

Product Description:

YJJ PN 281637 PN 282049 PN 282051 - Proximal Flow Sensors Are Suitable for Haimont Medical ventilators

 

 

Features:

Diameter (ID, OD [mm]) / Description

Material

1 Connector OD15, ventilator side PSU

2 Tubing-PVC

3 Connectors for tubing Differential pressure measurement PSU

4 Direction index--

5 Individual serial number--

6 Connector OD22/ID15, patient sidePSU

7 Flap-PET Details Flow range 0 to 180 l/min (short term 260 l/min) Dead space

< 11 ml (functional)

Resistance

< 0.027 cmH2O/(l/min) over the complete flow range (-180 l/min to 180 l/min)

Weight

Approx. 14 g without tubes, 68 g with 188 cm tubes, 89 g with 260 cm tubes, 110 g with 330 cm tubes

Material

Complies with ISO 10993-1:2009 (biocompatibility) and Directive 2011/65/EU (RoHS).

Does not contain natural rubber latex, DEHP, or BPA.

Accuracy

For calibrated flow sensor volume-related parameters:

HAMILTON-C1/T1/MR1/C2/C3/C6 ventilators: ± 10% or ± 10 ml (whichever is greater)

HAMILTON-G5/S1 ventilators: ± 15% or ± 20 ml (whichever is greater)

 

Specifications:

Temperature

Operating: -20°C to 50°C (-4°F to 122°F)

Storage: -20°C to 60°C (-4°F to 140°F)

Operating time 28 days or depending on hospital infection control protocols, patient secretions, and nebulization of medication
Accessory Tube clip, calibration adapter ID22 / OD15
Identification Individual serial number
Regulatory Hamilton Medical has established and applies a quality management system and fulfills ISO 13485 and ISO 9001. The flow sensor has been designed to comply with: Medical Device Regulation (EU) 2017/745, EN 980, EN 1041, ISO 5356-1, ISO 10993-1, ISO 14971

 